What Causes an AC Unit to Freeze Up in Wintersville, OH?

January 29th, 2026

4 min read

By Scott Merritt

AC freezing
What Causes an AC Unit to Freeze Up in Wintersville, OH?
6:58

Quick Answer

An AC unit freezes up in Wintersville most often because of restricted airflow, low refrigerant from a leak, dirty evaporator coils, electrical control problems, or systems running outside their original design limits. Split-level homes, finished basements, and long duct runs—common in Wintersville—make freeze-ups more likely. Running the system while it’s frozen almost always causes additional damage.

What To Do Immediately If Your AC Is Frozen

Turn the cooling off immediately.

Set the system to OFF, then switch the fan to ON to help thaw the ice. Do not restart cooling until the system is completely thawed and the cause is identified. Running a frozen AC can permanently damage the compressor.

Why You Can Trust This Explanation

I’m Scott Merritt, and I’ve been working in residential HVAC since 1994.

Over the last 30+ years, I’ve diagnosed, repaired, and replaced thousands of residential systems and trained hundreds of technicians across Ohio, including throughout the Upper Ohio Valley.

This article reflects repeat freeze-up patterns we see every summer in Wintersville homes, not generic HVAC advice.

Why AC Freeze-Ups Are So Common in Wintersville Homes

Wintersville homes stress AC systems differently than older city housing.

We commonly see:

  • Split-level and raised-ranch designs
  • Finished basements with limited return air
  • Long duct runs serving upper floors
  • Single systems cooling multiple levels
  • Thermostats located on mid-levels

Freeze-ups occur when airflow, refrigerant pressure, and runtime fall out of balance. In Wintersville layouts, that imbalance is common.

The Most Common Causes of an AC Unit Freezing Up

1. Restricted Airflow

This is the most common freeze-up cause we find in Wintersville.

Airflow is restricted by:

  • Dirty air filters
  • Undersized returns in split-level homes
  • Closed vents on lower levels
  • Ductwork that was never resized for finished basements

Low airflow drops coil temperature below freezing, allowing ice to form.

2. Low Refrigerant From a Leak

Refrigerant is sealed inside the system.

If it’s low, it leaked—often from:

  • Long refrigerant line runs
  • Aging copper line sets
  • Older joints from original installations

Low refrigerant lowers pressure, which drops coil temperature and causes icing.

3. Dirty Evaporator Coil

Basement air handlers in Wintersville commonly collect:

  • Dust
  • Pet hair
  • Remodeling debris

A dirty coil can’t absorb heat evenly. Cold spots form, moisture freezes, and ice spreads across the coil.

4. Electrical or Control Problems

Electrical issues can cause:

  • Incorrect blower speed
  • Extended runtimes
  • Short cycling followed by long cooling calls

When airflow and cooling output don’t match, freeze-ups become likely.

5. System Running Outside Its Design

Many Wintersville homes ask one system to cool:

  • Multiple levels
  • Finished basements
  • Added living space

Long run times combined with airflow limits are a frequent freeze-up trigger in this area.

Ice Location Matters: What You’re Seeing Tells a Story

  • Ice on the indoor coil: Usually airflow or refrigerant related
  • Ice on refrigerant lines only: Often airflow imbalance or metering issues
  • Ice on both the coil and lines: A system-wide imbalance

Where the ice forms helps narrow the cause quickly.

Why Freeze-Ups Usually Keep Coming Back

If an AC freezes once and the underlying cause isn’t corrected, it will almost always freeze again. Thawing the ice fixes the symptom, not the problem. This is one of the most repeat service issues we see in the Upper Ohio Valley.

How Maintenance Prevents Freeze-Ups

Freeze-ups usually develop over time as:

  • Filters slowly restrict airflow
  • Coils accumulate dirt
  • Small refrigerant leaks worsen
  • Duct changes reduce return air

Routine maintenance catches these issues early—before ice forms and damage occurs. Documented yearly maintenance is also required to keep repair and installation guarantees active.

A Real Wintersville Home Example

We worked on a split-level Wintersville home built in the early 1990s where the AC froze repeatedly during hot afternoons.

The causes included:

  • Restricted return airflow from the basement level
  • Low refrigerant from a small line-set leak
  • A dirty evaporator coil

Once airflow and refrigerant issues were corrected together, the freeze-ups stopped.

The Most Common Mistake Homeowners Make Here

Closing basement vents to push air upstairs.

This often reduces total airflow and causes the coil to freeze faster. Freeze-ups are airflow problems, not thermostat problems.

Who This Article Is (And Is Not) For

This is for you if:

  • You see ice on the indoor unit or refrigerant lines
  • Cooling fades before airflow stops
  • Your home has multiple levels or a finished basement

This may not apply if:

  • You have a brand-new system with a confirmed factory defect
  • You use ductless mini-splits
  • Ice forms only on a short exposed line section

What Guarantees Apply If Your AC Needs Repair

Honest Fix Service Trust Guardian (Repairs & Diagnostics)

Freeze-up repairs are protected by our Service Trust Guardian, which includes:

  • A 5-year labor warranty on covered repairs
  • A 60-day satisfaction guarantee
  • No overtime or after-hours charges
  • On-time arrival and clean-work commitments

These guarantees remain active with documented yearly maintenance, consistent with manufacturer requirements.

If Freeze-Ups Lead to System Replacement

Honest Fix Lifetime Trust Shield (New Installations)

If replacement becomes the right decision, new systems are protected by our Lifetime Trust Shield, which includes:

  • Long-term labor coverage
  • A full money-back satisfaction period
  • A no-lemon replacement guarantee
  • Energy performance accountability
  • Apples-to-apples price protection

These protections are written and designed for homeowners in the Upper Ohio Valley.

Other Ohio Valley Communities Where AC Freeze-Ups Are Common

We see similar freeze-up patterns in nearby towns, including:

  • Steubenville, OH
  • Toronto, OH
  • Mingo Junction, OH
  • Brilliant, OH
  • Weirton, WV
  • Follansbee, WV
  • Wellsburg, WV
  • New Cumberland, WV
  • Colliers, WV
  • Hooverson Heights, WV

Frequently Asked Questions

Should I run my AC if it’s frozen?

No. Running it while frozen can cause serious damage.

Is freezing always a refrigerant problem?

No. Restricted airflow is the most common cause we see.

What guarantees do you offer?

Repairs are protected by the Service Trust Guardian.

New installations are protected by the Lifetime Trust Shield.

What To Do Next

An AC freeze-up is a clear warning that airflow, refrigerant, or system balance is off. Addressing it early prevents much larger failures.

Call Honest Fix today for a free exact quote.

You can also learn about our guarantees before you decide.

::contentReference[oaicite:0]{index=0}

Scott Merritt

Scott Merritt is a co-founder of Honest Fix Heating, Cooling and Plumbing and brings more than 30 years of experience across HVAC, leadership, and industry education. He serves in a senior leadership and oversight role, providing licensed guidance, reviewing HVAC educational content, and supporting technician training and documentation standards. Prior to co-founding Honest Fix, Scott founded and owned Fire & Ice Heating & Air Conditioning in Columbus, Ohio, which he operated for more than two decades before selling the company in 2025. During that time, he led programs and partnerships including Carrier Factory Authorized Dealer, Trane Comfort Specialist, and Rheem Pro Partner, helping establish high technical and training standards. Scott is the Ohio State HVAC license holder for Honest Fix and provides licensed oversight to help ensure work meets applicable codes and manufacturer requirements. Learn more about Scott’s background and role at Honest Fix by viewing his full leadership bio.